Minimize THD in multilevel inverters with switching angles calculated

Minimize THD in multilevel inverters with switching angles calculated

Mohammad Kazeminejad1 khodakhast esapour2 Mohammad tajali ardakani3

1) Master of Science in Electrical Control Azad University Abarkuh
2) Vocational school teacher MARVDASHT
3) PhD student at Azad University of Khorasgan

IOI Code : XYFD-BBCZC
Publication : international conference on innovation in Science & Technology(istconf.com)
Abstract :
    The power electronic devices in various types and for various applications have been made, as one of the most important and widely used in the inverter devices are.In this article inverter types in MATLAB Simulink simulation,Then a review is done on the inverter output waveform is an example,Since one of the crucial disadvantages of using modulation bandwidth is optimizedThe optimum switching angles can not be estimated in real time and must be pre-calculated angles it is found in the lookup table,This paper presents a new algorithm to calculate the angles to get real-time keying offers,The minimum total harmonic distortion for the modulation stairs.The minimum output voltage THD is to prove that the mathematical models haveWe algorithm on a digital signal processor implementation and results confirmed the performance of the proposed algorithm is that we have to offer.

Keywords : harmonic distortion pulse width modulation digital signal