simulation and analysis of the effect of the high pressure feeding water heater on the efficiency of shahid beheshti steam power plant

simulation and analysis of the effect of the high pressure feeding water heater on the efficiency of shahid beheshti steam power plant

shahab amrollahi1 hadi mirzayi2 abolfazl hajizade aghdam3

1) arak university of technology :
2) arak university of technology :
3) arak university of technology :

IOI Code : XYGD-BCHFC
Publication : The 5th International conference of Sciences and Engineering(5icesconf.com)
Abstract :
    In the initial design to enhance the efficiency of steam power plants, water temperature entering the boiler rises by feed water heaters. With the removal of these components from steam power cycle, efficiency can be changed. This paper aim simulation and analysis of the effect of the high pressure feeding water heater on the efficiency of shahid beheshti steam power plant with individual unit capacity of 200MW. EES (Engineering Equation Solver) software and thermoflow software is used for performing analyses. The results show that the total efficiency of the cycle is 35.57%. By removing the high pressure heater Number (7) The efficiency decreases 35.37% , By removing the high pressure heater Number (6) The efficiency decreases 35.38% , By removing the high pressure heater Number (5) The efficiency decreases 35.49% and By removing the high pressure heaters Number (5)&(6)&(7) The efficiency decreases 34.79% .

Keywords : shahid beheshti steam power plant energy efficiency exergy efficiency thermoflow heater