The behavior of perforated steel shear walls reinforced with FRP sheets
The behavior of perforated steel shear walls reinforced with FRP sheets
Gholamreza Ghodrati Amiri1 Seyed Amir Hashemi Amiri2
1) Professor ،Schoolof Civil Engineering Iran Universityof Science
2) Islamic Azad University of Bandar
IOI Code
:
XYHA-BECGA
Publication :
The 4th International conference of Science and Engineering(4icesconf.com)
Abstract :
Abstract1
Previously in the steel shear wall was used from thick sheets or plates with hardener to prevent early local buckling of filler plates. But recently the idea of using a diagonal tension field after the buckling of thin steel plates has been take into consideration of many researchers. Recent researches have shown that buckling of these plates prior to the submission of environmental elements will lead to the better performance of this type of systems since using the plats with a thickness less than 1.5mm does not have a good performance in a steel shear wall, so illustrates the importance of steel plate shear wall with perforated sheet filler being new to this system and lack of administrative procedures about providing a good model in arrangement of holes has created considerable problems. Creating holes in surface whit an integrated function generate weaknesses in energy absorption, stiffness and shear capacity of the system. For this purpose, using of FRP sheets in order to overcome these drawbacks has been used in this Article. Reinforced polymers whit FRP fiber are resistant and durable and at the same time light materials with having good mechanical properties are used on most surfaces. In this Article we have tried to use the ABAQUS software to evaluate diagrams of push-over derived from analysis of 72 models of perforated steel plate shear wall with both 1.5 and 2.6 mm thick reinforced with FRP sheets under increased lateral of alignment holes. The effect of the angel of the holes relative to the vertical direction as well as energy absorption, shear capacity of system, buckling out of the plate the filler sheets. Hysteresis curves obtained from Vian and Bruneau experiments on steel shear walls without holes and the push-over curves obtained from ABAQUS software have a very good adaptation with each other. The results show that in the perforated steel plate shear wall with both thickness and stiffener, we will have a dramatic increase in shear capacity and energy absorption.
Keywords : shear walls perforated shear plates stiffener push over curve buckling