Effect of column panel zone thickness on the base shear of special moment frames

Effect of column panel zone thickness on the base shear of special moment frames

amirbahador rouhi1 amirahmad hedayat2

1) Islamic Azad university
2) Islamic Azad university

IOI Code : XYZA-ZZACA
Publication : 2nd International Conference On Modern Researches in Civil Engineering, Architecture And Urban Development(2cauconf.com)
Abstract :
    The column panel zone has a significant effect on the seismic behavior of steel special moment frames. However, these days there is no single comments about the panel zone condition. In other word, there is an argument between the designers whether this source of seismic energy dissipation must be used or neglect this source. The aim of this study was to investigate the effects of different panel zone conditions on the seismic behavior of special moment frames. for this purpose Three 2٬ 4 and 6 stories frames with weak, balance and strong panel zone conditions were modeled using opensees software and were subjected to 30 ground motions and nonlinear dynamic analyzes were performed. Fragility curves for these two frames for two different seismic hazards, DBE and MCE, for parameters, Normalized base shear were drawn. Results showed that for majority of cases, increase in the panel zone thickness did not lead to the achievement of a better performance. In addition results showed that for some cases, increase in the panel zone thickness caused an increase in the rotation of the beam and column plastic hinge. It finally promoted the collapse of whole structure.

Keywords : panel zone base shearspecial moment frame fragility curve