Review of Gas Turbine & Gas Compressor performance curve at Gas Boosting station
Review of Gas Turbine & Gas Compressor performance curve at Gas Boosting station
Mahdi Zare1
1) Head OF engineering Depatment at NIGTC
IOI Code
:
XYZG-ZABFF
Publication :
2nd International Conference on Science and Engineering(2icesconf.com)
Abstract :
Increasing gas transporting efficiency is one of important challenges of specialists in order to save energy consumption in variety ways. Turbo-compressors are vital machines at gas boosting stations، which are major players of energy conversion. In their performance curves، there is a region which within it efficiency of axial compressor، turbine blades and centrifugal compressor polytropic efficiency is maximum. At this paper، this region would be identified, which is vital at selection, purchasing and operation. Also، performance calculation and corresponding curves would be given. At the end، effect of different parameters on operation of gas compressor has been evaluated and some advises are given to save more energy.
Keywords : gas turbine axial and centrifugal compressor performance curves and efficiency