Titania-Ceria-Graphene Quantum Dot Nanocomposites as New Modifiers for Determination of Dopamine in The Presence of Ascorbic Acid and Uric Acid
Titania-Ceria-Graphene Quantum Dot Nanocomposites as New Modifiers for Determination of Dopamine in The Presence of Ascorbic Acid and Uric Acid
Nasrin Ahmadi1 Mojtaba Bagherzadeh2 Ali Nemati3
1) Department of Materials Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran, E-mail:
2) Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute, 81465-1589, Isfahan, Iran, E-mail:
3) Department of Materials Science & Engineering, Sharif University of Technology, Tehran, Iran, E-mail:
IOI Code
:
XBCG-DCCEH
Publication :
13th Biennial Electrochemistry Seminar of Iran(elect13pguac.ir)
Abstract :
Dopamine (DA) is one of the most important neurotransmitters in the mammalian brain that has a substantial role in the function of the central nervous, renal and hormonal systems. Various analytical techniques have been used to determine of DA [1]. However, due to electroactivity of DA, the electrochemical methods appear to be suitable for its quantitative determination. Nowadays, new nanomaterials are being used in the construction of the new electrodes for electrochemical sensing of DA [2-3]. A sensitive and selective DA sensor based on Titania-Ceria-Graphene Quantum Dot (TC-GQD) nanocomposite modified glassy carbon electrode (GCE) are presented for the first time, here. Graphene quantum dots (GQD), Titania-Ceria (TC) and TC-GQD nanocomposites were synthesized by hydrothermal and sol-gel methods [4-5], and then characterized by FTIR, FESEMand EDS techniques. The electrochemical responses of the GQD (GQD/GCE), TC (TC/GCE) and TC-GOD (TC-GQD/GCE) modified GCE towards DA, ascorbic acid (AA) and uric acid (UA) were evaluated by using CV and DPV techniques, and also affecting parameters like pH on their response were studied and optimized for each electrodes. Selectivity of the prepared electrodes towards DA, linear ranges, figure of merits and detection limits of the electrodes calculated and compared with together in this work and will be presented and discussed. Our findings showed that the electrochemical sensor based on TC-GQD/GCE, successfully detected DA in the presence of AA and UA, in the wider linear range, 0.1-500 μM, and lower detection limit, 0.04 μM, than the other electrods in this work.
Keywords : electrochemical sensor dopamine nanocomposite titania ceria graphene quantum dot