Direct electron transfer of glucose oxidase and biosensing for glucose on carbon nanofibers (CNFs) and N-doped graphene quantum dots (NGQDs) composite
Direct electron transfer of glucose oxidase and biosensing for glucose on carbon nanofibers (CNFs) and N-doped graphene quantum dots (NGQDs) composite
Samira Yazdanparast1 Ali Benvidi2 Saleheh Abbasi3
1) Iran, Yazd University, Department of Chemistry, Faculty of Science. Email:
2) Iran, Yazd University, Department of Chemistry, Faculty of Science. Email:
3) Iran, Yazd University, Department of Chemistry, Faculty of Science. Email:
IOI Code
:
XBCG-DCCZB
Publication :
13th Biennial Electrochemistry Seminar of Iran(elect13pguac.ir)
Abstract :
Glucose oxidase (GOD) is a flavin enzyme with FAD (flavin adenine dinucleotide)/FADH2
as the redox prosthetic group (active center) [1, 2]. GOD has been successively employed to
fabricate glucose biosensors. Constructing an enzyme-labeled electrochemical glucose biosensor may possess some prominent advantages over nonenzymatic sensors, including much higher electrocatalytic activity toward analyte [3, 4]. The most widely used technique for enzyme glucose sensors is amperometry [5]. In the amperometric sensors, GOD oxidizes glucose to gluconic acid in the presence of oxygen. however, in hydrodynamic amperometric condition, the concentration of oxygen changes during the rotation of the electrode and maintaining a stable oxygen concentration becomes difficult. In the present work, an enzyme labeled electrochemical biosensor was fabricated for sensitive glucose detection. A hybrid nano-interface comprising a blend of carbon nanofibers (CNFs) and N-doped graphene quantum dots (NGQDs) was employed as a novel immobilization platform for glucose oxidase (GOD). The new nanocomposite can provide a larger surface area and favorable direct electron transfer between GOD and the electrode. The GOx immobilized on CNFs-NGQDs composite exhibits well-defined redox peaks with a peak potential separation (ΔEp) of about 30 mV with enhanced peak currents, indicating a fast electron transfer at the modified electrode surface. The optimization of the amount of nanocomposte, temperature and enzyme concentration was performed in detail. Differential pulse voltammetry (DPV) was employed to investigate the determination performance of the enzyme biosensor, resulting in a linear response range from 1.0 to 15.0 mM with an optimal detection limit of 0.15 mM. and The practicality of this sensor has been demonstrated in human serum samples, providing great potential in clinical applications.
Keywords : glucose oxidase biosensor differential pulse voltammetry nanocomposite