Fatigue Behavior of Shear Studs in Steel-Concrete Composite Bridge Girders
Fatigue Behavior of Shear Studs in Steel-Concrete Composite Bridge Girders
Mohammad Saeed Mafipour1 Sepehr Tatlari2 Amir Reza Ghiami Azad3 Moslem Shahverdi4 Soheil Mohammadi5
1) MSc Student, School of Civil Engineering, College of Engineering, University of Tehran,
2) MSc Student, School of Civil Engineering, College of Engineering, University of Tehran,
3) Assistant Professor, School of Civil Engineering, College of Engineering, University of Tehran,
4) Assistant Professor, School of Civil Engineering, College of Engineering, University of Tehran,
5) Professor, School of Civil Engineering, College of Engineering, University of Tehran,
IOI Code
:
XBFA-DFZDD
Publication :
3rd International Conference on Applied Research in Structural Engineering and Construction Management(sharifsecm.ir)
Abstract :
Fatigue is one of the main limit states in the design of shear stud connectors of steel-concrete composite bridges. In order to control fatigue in shear connectors, provisions mainly propose S-N curves. However, these curves have mostly been based on a limited number of experiments although many other S-N curves have been reported which are different. To address this issue, extensive data of conducted experiments on headed shear studs since 1950 are collected in this study, effects of various parameters on the fatigue behavior of headed shear studs are investigated. Finally, a three-level master curve is presented to evaluate the fatigue behavior of shear studs in steel-concrete composite bridge girders.
Keywords : fatigue shear studs bridge s n curves