Experimental Study on the tensile capacity of adhesive anchors in reinforced concrete sections
Experimental Study on the tensile capacity of adhesive anchors in reinforced concrete sections
Sahand Sartipi1 Siamak Epackachi2
1) Graduate Student, Amirkabir university of technology,
2) Assistant Professor, Amirkabir university of technology,
IOI Code
:
XCZG-EEEHC
Publication :
International Conference on Civil Engineering, Architecture , Development and Recreation Urban Infrastructure in Iran(icdu.ir)
Abstract :
The adhesive bonded anchors are widely used in the rehabilitation and strengthening of old or damaged concrete structures. These anchorage systems are most commonly installed in a variety of sections, such as concrete slabs as well as concrete beams and columns. The behavior and failure modes of these anchorage systems are reliant on various parameters. Herein, the effects of vertical and horizontal steel reinforcement are studied using a set of 36 experiments. These experiments were conducted on 6 concrete specimens similar to everyday reinforced concrete beams and columns. The results indicate that reinforcement increases the tensile capacity of adhesive bonded anchors only in group formations with deep embedment depths. Based on the test results, various recommendations and suggestions are made.
Keywords : adhesive bonded anchor post installed anchor chemical anchor experimental study