Experimental Study of an All-Steel Two-Segment Core Buckling Restrained Brace
Experimental Study of an All-Steel Two-Segment Core Buckling Restrained Brace
Mohammad Javad Goodarzi1 Freydoon Arbabi2
1) Instructor, Technical and Vocational University (TVU), Kermanshah, Iran
2) Professor, Dept. of Structural Engineering, International Institute of Earthquake Engineering and Seismology (IIEES), Tehran, Iran
IOI Code
:
XCZG-EGKEG
Publication :
International Conference on Civil Engineering, Architecture , Development and Recreation Urban Infrastructure in Iran(icdu.ir)
Abstract :
Buckling Restrained Braces (BRBs) have been exceedingly used for resisting seismic forces in framed structures. However, their design criteria are not fully established yet. In other words, existing codes do not specify the process of design of buckling restrained braces. A type of fully steel brace has been designed in the present study that provides ease of construction and replacement of the core. The end parts of the core and shield are so designed as to eliminate the problems that have existed in the previous designs. the core consists of two segments that can go plastic. In all these specimens, the geometry and materials were the same and only the lengths of the yielding core elements were different. These specimens were tested under quasi-static loading up to a target displacement. The results for all three specimens tested show that minimum values of parameters specified by the AISC Steel code (maximum compressive stress factor, = 1.3, and minimum energy absorption factor η=200) have been achieved and in all cases they exceeded the code requirements by a large margin ( , ). each specimen was capable of carrying several additional cycles of loading (11 or more) at the end of the test. Cyclic behavior of the specimens showed high energy absorption capabilities with strains of up to 4.6%. The idea of using multi-zone cores not only allows a better distribution of plastic region but also enables us to stabilize the shield to the core at the middle zone, where no plastic deformation takes place. In this way, the stability of the shield is achieved by a simple mechanism without requiring elaborate details of a stopper.
Keywords : buckling restrained mechanism shield fatigue core length sliding stopper