A sustainable approach for efficient removal of phenolic contaminates from water through DBD non-thermal plasma method
A sustainable approach for efficient removal of phenolic contaminates from water through DBD non-thermal plasma method
Amirhossein Khourshidi1 Fatemeh Ajam2 Mobina Golbabai Kotenai3 Sara Akbari4 Poone Yaquobnejad5 Masoud Rabieian6 Mohsen Taghavijeloudar7
1) Master student of Environment Engineering, Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran
2) Master student of Environment Engineering, Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran
3) Master student of Environment Engineering, Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran
4) Master student of Environment Engineering, Faculty of Civil Engineering, Babol Noshirvani University of Technology, Babol, Iran
5) MSc. Department of Civil and Environmental Engineering, Babol Noshirvani University of Technology,47148-71167, Babol, Iran;
6) PhD. Student Department of Civil and Environmental Engineering, Babol Noshirvani University of Technology,47148-71167, Babol, Iran;
7) Department of Civil and Environmental Engineering, Seoul National University, 151-744, Seoul, South Korea;
IOI Code
:
XGZK-KZGZE
Publication :
7th International Conference on Applied Researches in Science & Engineering (7carse.com)
Abstract :
This research focuses on the evaluation of non-thermal plasma as a sustainable and effective solution for the removal of 4-nitrophenol (4-NP), a hazardous contaminant classified by the Environmental Protection Agency (EPA). The study investigates the influence of key operating factors, namely initial pH, applied voltage, and initial concentration of 4-NP, on the performance of the dielectric barrier discharge (DBD) system, aiming to identify optimal conditions. Comparative analysis is conducted to assess the results in relation to existing methods reported in the literature. The findings demonstrate that non-thermal plasma exhibits remarkable efficiency in reducing 4-NP concentrations in polluted water, achieving removal rates of up to 98%. Optimum conditions for maximum degradation are identified as pH 11, applied voltage of 22 kV, and initial concentration of 200 mg/l. These results underscore the potential of DBD as an environmentally friendly and efficient method for the degradation of 4-NP, outperforming other techniques.
Keywords : wastewater treatment 4 np dbd plasma aops