The validation Analysis of some plume rise Formulas

The validation Analysis of some plume rise Formulas

Maryam Arehjani1 Maryam Shabani2 Davood Kahforoushan3 Esmaeil Fatehifar4

1) Faculty of Chemical Engineering, Sahand University of Technology, Tabriz, Iran,
2) Ph.D Student, Faculty of Chemical Engineering, Sahand University of Technology, Tabriz, Iran,
3) Associate Professor of Chemical Engineering, Faculty of Chemical Engineering, Sahand University of Technology, Tabriz, Iran,
4) Professor of Chemical (Environmental) Engineering, Faculty of Chemical Engineering, Sahand University of Technology, Tabriz, Iran,

IOI Code : XYAA-ZBCBB
Publication : 2nd International conference on sustainable development, strategies and challenges With a focus on Agriculture, Natural Resources, Environment and Tourism(2icsda.ir)
Abstract :
    Tall stacks are used common tools for reducing ground level concentrations. The plume rise plays an important role for this purpose. Although, too many equations are offered to calculate the plume rise of these stacks, the selection of them is complicated by the fact that no one formula can apply to all situations. In this paper two examples of famous equations were selected to carry out the validation study. For this purpose two series of actual data reported by Bringfelt and Sunder were used to compare Holland and Moses & Carson plume rise equations using regression technique. Moses & Carson equation was better in agreement with Bringfelt data. But none of those equations were not in well agreement with all data. So, the recommended equations should be used over the range of variables upon which they were derived.

Keywords : plume rise stack regression validation air pollution