Effect of Side-Dump Angle on Outlet Parameters in A Side-Dump Simulator

Effect of Side-Dump Angle on Outlet Parameters in A Side-Dump Simulator

Mohammad Mahdi Doustdar1 Mohammad Mojtahedpoor2

1) Associated proffessor of Imam Hossein University
2) Ph.D student of Malek-Ashtar University

IOI Code : XYCC-ABCHF
Publication : International Conference on Science and Engineering(icesconf.com)
Abstract :
    In this study three-dimensional air mixing in side-dump combustor with fuel injectors whick located in quad rectangles side-dumps are numerically investigated. A comparison between side-dump combustors of 45 and 90 degrees have been done. Side-dump angle of 90 degrees is cross to the combustor simulator and the side-dump angle of 45 degrees is according to entrance stream. For the calculation a modified version of KIVA-3V code has been used. To investigate the flow, cold flow enters to the combustors simulators and fuel will be injected cross flow to the combustors. We have investigated the mean radius of outlet fuel droplets, outlet velocity and effective mass fraction in different initial conditions. The mass of fuel vapor inside the flammability range is named effective mass fraction. In accordance with results, the outlet velocity in side-dump angle of 45 degrees is more than side-dump of 90 degrees and radius of outlet fuel droplets in side-dump angle of 45 degrees is smaller than side-dump of 90 degrees.

Keywords : effective mass fraction side dump combustor mean radius of fuel droplets outlet velocity kiva 3v code