Identification of gamma rays yielded from positron decay emitted from 22Na source with coincidence measuring of gamma rays

Identification of gamma rays yielded from positron decay emitted from 22Na source with coincidence measuring of gamma rays

Farhad Zolfagharpour1 Roghaye Sohrabi2 Meysam Ghaebi3 Maryam Noorani4

1) Department of physics, University of Mohaghegh Ardabili, Ardabil, Iran
2) Department of physics, University of Mohaghegh Ardabili, Ardabil, Iran
3) Department of physics, Univer sity of Damghan, Damghan, Iran
4) Department of physics, University of Mohaghegh Ardabili, Ardabil, Iran

IOI Code : XYDK-AHACH
Publication : International Conference On Research Science And Technology(restconf.com)
Abstract :
    In this paper, coincidence intensities of 511 keV gamma rays yielded from electron and positron decays emitted from 22Na source, are measured using two NaI detectors with timing response of 4 micro seconds. The experiment is done under angles of 90º, 180º and 270º with respect to detectors in two situations: First they are shielded using a lead shield and a lead window and then they are unshielded. The resultant gamma ray spectra in detectors are recorded in coincidence and normal modes. Due to Campton scattering, the gamma rays can be scattered in angles other than 180º and with increasing or decreasing the scattering angle, the recorded gamma ray intensities decrease. Our results show that in the case in which the lead window is considered and the gamma rays are coincident, with changing the scattering angle, the peak area in gamma spectrum in 511 keV energy reduces to zero faster than the case in which the lead window is not considered. This shows that using the lead window, the Campton scattering reduces. Also, without the lead window, the recorded gamma ray intensity in terms of the scattering angle, is compatible with Klein-Nishina equation.

Keywords : coincidence nai detector positron 22na source