Energy and diameter treatment of electron beam in accelerator tube by increasing the radius of the crater and the distance between the electrodes accelerator
Energy and diameter treatment of electron beam in accelerator tube by increasing the radius of the crater and the distance between the electrodes accelerator
Mehdi Simiyari1 Ramin Roozehdar Mogaddam2 Mehdi Amiri3
1) Faculty of Science, Emam Ali University, Tehran, Iran-Email:M.
2) Faculty of Science, Emam Ali University, Tehran,
3) Department of physics, University of Mohaghegh Ardabili, Ardabil,
IOI Code
:
XYGD-BCHDA
Publication :
The 5th International conference of Sciences and Engineering(5icesconf.com)
Abstract :
The column of electron electrostatic accelerator is one of the critical components in electrostatic accelerator. The geometrical design of such accelerator must be as such that in the case of applying voltage to its electrodes, not only should its equipotential surfaces and its gradient accelerate the beam particles up to desired energy, but also it should focus the beam and hinder broadening of energy distribution of accelerated particles. Accelerator electrodes which are used in accelerator tubes can have different geometries. In the first geometry interior radius of electrodes are assumed fixed and in the second they are spotted transitive if the radius of each electrode to previous electrodes is more with a fixed rate. The energy and diameter treatment of both geometries shows that the second introduces an optimal state and output beam has less diffusion and high energy.
Keywords : accelerator tube immersed lens in the field axial potential distribution electrode