More effective cooling-reinforced solid-phase microextraction of polycyclic aromatic hydrocarbons from polluted soils by creating distance between cooling and heating zones
More effective cooling-reinforced solid-phase microextraction of polycyclic aromatic hydrocarbons from polluted soils by creating distance between cooling and heating zones
Ali Reza Ghiasvand1 Fatemeh Yazdankhah2 Mina Behfar3
1) Professor-Analytical Chemistry-lorestan university.
2) Ph.D student- Analytical Chemistry-lorestan university.
3) Ph.D student- Analytical Chemistry-lorestan university.
IOI Code
:
XYGD-BCKAD
Publication :
The 5th International conference of Sciences and Engineering(5icesconf.com)
Abstract :
In cooling-reinforced solid-phase microextraction (CR-SPME), the sample is heated to a high temperature and the extraction phase simultaneously cooled to a low temperature. This simultaneous heating/cooling process causes significant increasing of the sample/headspace and headspace/fiber partition coefficients. In this research, the effect of the distance between the cooling zone (extraction phase) and the heating zone (sample matrix) on the efficiency of cooling-reinforced solid-phase microextraction (CR-SPME) of PAHs from soil samples was studied. Determination of the analytes was carried out using high performance liquid chromatography with UV detection (HPLC-UV). Increasing the distance between the cooling and heating zones in CR-SPME increases the thermal gap between the zones and consequently increases the extraction efficiency. Different experimental factors that may influence the extraction efficiency, including location of the cooling device, sample matrix temperature, fiber temperature, extraction time, type and volume of eluting solvent and elution time were evaluated and optimized. The highest extraction efficiency was obtained using a cooling device with external position, extraction temperature of 200°C, fiber temperature of -25°C, extraction time of 15 min and 30 μL of acetonitrile, as the eluting solvent. Good linearity (R2>0.99) was obtained for the calibration curves over the concentration range of 1-10000 ngg-1. The limits of detection (LODS) for five PAHs were found to be 0.1-0.9 ngg-1. The relative standard deviations (RSD %) for six replicated analysis of 1 ngg-1 of PAHs were calculated 8.7-17.1%. The developed CR-SPME-HPLC method was applied for direct extraction and determination of PAHs in contaminated soil samples and the results showed good agreements with a validated ultrasound-assisted solvent extraction (UA-SE) standard method.
Keywords : cooling reinforced microextraction (cr me) heating zone cooling zone pahs polluted soil