Overview of Design Requirements of Different Standards and Database for Transfer Length in Prestressed Normal and Self-Consolidating Concrete
Overview of Design Requirements of Different Standards and Database for Transfer Length in Prestressed Normal and Self-Consolidating Concrete
Fatemeh Azadpour1 Ali Akbar maghsoudi2
1) PHD student, Department of civil Engineering, Shahid bahonar university of Kerman,
2) Associate Professor, Department of civil Engineering, Shahid bahonar university of Kerman, Kerman, Iran
IOI Code
:
XYGD-BCKDH
Publication :
The 5th International conference of Sciences and Engineering(5icesconf.com)
Abstract :
The study presented in this paper was intended to compare the design requirements in transfer length for pre-tensioned concrete structures of three different structural building standards as ACI 318M-11, BS8110:1997, and EuroCode2:2004. These Codes have been compared in the design requirements of pre-tensioned concrete elements, and identifies similarities and differences between these codes. Although the principles are generally the same, they differ in details that the transition among the codes is not a difficult process. Because of the importance of transfer length for pretensioned concrete elements, it is focused. So, an experimental database of several authors on different types of pretensioned concrete as Normal concrete(NC), high strength concrete(HSC), self-consolidating concrete (SCC) and high strength self-consolidating concrete (HSSCC), has been complied and compared with predictions according to Code provisions. The predicted values from BS8110 and EC2 was varying vastly as considering concrete properties. On average, the predicted values are greater than the experimental values in the transfer length models. Higher values corresponds to high strength concrete, so it seems that Code provisions are so conservative for high strength concrete. The transfer length ratio (calculated/measured) shows a tendency in which these ratio decrease when the measured transfer lengths increase. And also, it was seen that the number of underestimated cases increase by the strand diameter.
Keywords : structural building codes transfer length