Economic and Environmental Evaluation of Arranging Different Insulators and PCM in External Walls of Buildings under Various Climates Conditions of Iran

Economic and Environmental Evaluation of Arranging Different Insulators and PCM in External Walls of Buildings under Various Climates Conditions of Iran

Mehrdad Sarabi1 Hadi Ghaebi2 Ebrahim Abdi Aghdam3

1) Department of Mechanical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran.
2) Department of Mechanical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran.
3) Department of Mechanical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran.

IOI Code : XYGE-BDAGG
Publication : 3rd International Conference on Engineering and Applied Science (3iceasconf.com)
Abstract :
    One of the essential elements of building design is simulation and estimation of energy consumption prior to construction using simulation softwares. In order to estimate the thermal energy consumption of the building, these softwares generally do the calculation hourly during the year. Most of these softwares cannot automatically show the ideal conditions and the user should make several cases and then find the ideal situation by evaluating the result. Simulation, optimizing energy consumption, economic and environmental analysis (CO2 production) in a sample building with different insulator layers and PCM in north and south external walls was done in this study using a building energy optimizer software in four different climates of Iran (Ardabil, Tehran, Bandar Abbas and Yazd) during a 30 year period. Two types of insulators polystyrene and poly-roll and a sample of PCM (paraffin) are selected. The reduction of energy cost in 30 years with different layers of insulators in external walls was obtained by considering to place, type, and thickness of insulators, and changing climate. The results show that the most reduction in energy consumption respectively occurred after insulating of the north and south external walls of Tehran and Ardabil with 75 mm, and the one was in Bandar Abbas for external south walls with 50mm, and external north walls with 75mm polystyrene. Also the minimum CO2 emission was for north and south external walls with 75mm polystyrene in Bandar Abbas.

Keywords : economic analysis thermal insulator pcm co2 emission building energy consumption