The impact of increased bay and height of buildings have a shear wall on Redundancy coefficient

The impact of increased bay and height of buildings have a shear wall on Redundancy coefficient

Mahdi Bamdad1 Abdoreza Sarvghad Moghadam2

1) Department of Civil and Environmental Engineering, Islamic Azad University, South Tehran Branch
2) Associate Professor, International Institute of Earthquake Engineering and Seismology.

IOI Code : XYHA-BECCK
Publication : The 4th International conference of Science and Engineering(4icesconf.com)
Abstract :
    Redundancy coefficient is considered as important parameter with a significant role in the optimal and economic design of structures and the value of their behavior factor. The goal of this paper was to study the redundancy coefficient of 6, 8, and 10 storey RC frames with RC shear walls by changing different parameters and evaluating the results through a numerical approach using finite element modeling in ABAQUS software. This procedure was used to evaluate the effect of seismic parameters, the number of bays, and the number of shear walls. To verify the validity of finite element model, the loading history and hysteresis plots of a real RC frame experiment was compared with the simulated results obtained by the used model. It was observed that for a structure with fixed length, as the height of structure increased, its redundancy coefficient decreased. Also, the ductility of structure decreased significantly with the increase in the number of bays having a shear wall.

Keywords : redundancy coefficient rc frame shear wall