Piezoelectric Response and Fibroblast Adhesion in BaTiO₃/ZnO-PVA/CMCS Hydrogel

Piezoelectric Response and Fibroblast Adhesion in BaTiO₃/ZnO-PVA/CMCS Hydrogel

Asma Salimi1 Zahra Mohammadi2

1) MSc Student. Specialized Laboratory of Bioceramic and Implant, Department of Medical Engineering (Medical Technology & Tissue Engineering), College of Interdisciplinary Science and Technology, University of Tehran, Tehran, Iran;
2) Corresponding Author: Associate Professor, Head of Specialized Laboratory of Bioceramic and Implant, Department of Medical Engineering (Medical Technology & Tissue Engineering), College of Interdisciplinary Science and Technology, University of Tehran, Tehran, Iran;

IOI Code : ABEB-ACZFAH
Publication : 4th International Conference on Recent Advances in Engineering, Innovation and Technology - Belgium(eitconf.com)
Abstract :
    Chronic wounds remain a major challenge in tissue repair, partly because traditional dressings primarily provide passive protection and do not actively respond to the electrical microenvironment of injured tissue. This study aimed to develop and characterize a piezoelectric nanocomposite hydrogel based on polyvinyl alcohol/carboxymethyl chitosan (PVA/CMCS) for potential use as an electroactive wound dressing. The hydrogel was reinforced with 5 wt% barium titanate (BaTiO₃) and 10 wt% zinc oxide (ZnO) nanoparticles and fabricated through repeated freeze–thaw cycles followed by CaCl₂ treatment. Nanoparticle incorporation substantially altered the mechanical properties, increasing the compressive modulus from 0.244 MPa for the blank PVA/CMCS hydrogel to 21.70 MPa for the nanocomposite, corresponding to an approximately 89-fold increase. In contrast, the strain at maximum stress decreased from 78.74% to 5.36%, indicating a markedly stiffer and less deformable structure. Under cyclic compression, the nanocomposite exhibited a repeatable electromechanical response, with an average peak-to-peak voltage of 194.0 ± 47.0 mV and an RMS output of 13.0 ± 0.1 mV. The generated electrical response was within the range of electrical potentials discussed for wound-healing environments, although the measurements were obtained under controlled laboratory compression. Indirect MTT assays using L929 fibroblasts showed cell viability across the tested extract concentrations and exposure times. SEM observations further demonstrated fibroblast attachment and spreading, with cellular extensions contacting the hydrogel surface. Overall, BaTiO₃/ZnO incorporation enhanced the stiffness of the PVA/CMCS hydrogel while providing a repeatable electromechanical response and supporting fibroblast attachment under the tested conditions, highlighting its potential for further investigation as an electroactive wound dressing.

Keywords : piezoelectric hydrogel barium titanate zinc oxide electroactive wound dressing fibroblast adhesion