Optimization of commercial building energy performance in Isfahan city based on atrium geometric specifications
Optimization of commercial building energy performance in Isfahan city based on atrium geometric specifications
Saadat Bakhshi1 Abdolreza Pourhomayoun2
1) Master of Architecture; Islamic Azad University; Isfahan Branch
2) PhD in Architecture, Islamic Azad University, Isfahan Branch,
IOI Code
:
AAHF-ABKCFC
Publication :
National Conference on Architecture and Art Technologies, Smart City, Soft and Creative Industries and Technological Culture(icact.ir)
Abstract :
The complexity of atrium design and the impact of various geometric parameters on building energy performance are a major challenge in contemporary architecture, as improper design of these spaces can lead to a significant increase in energy loads. The present study aimed to investigate the impact of atrium geometric characteristics on the energy performance of mid-rise commercial buildings in the hot and dry climate of Isfahan and to present a predictive model based on computational design and simulation. The research method has a mixed approach and is organized in six main stages including literature review, initial design, parametric modeling of the building, energy performance optimization, regression modeling, and final design. The geometric parameters considered include the length and width of the atrium cross-section, the atrium position in the plan, the atrium height from the building roof, the atrium window-to-wall ratio, and the window-to-wall ratio of the building facades. The simulation process was performed using Ladybug Tools on the Grasshopper platform, and multi-objective optimization was performed based on the non-dominated genetic algorithm version 2 (NSGA-II) in the form of 9000 simulations in three separate processes with 100 generations and an initial population of 30 samples. The research findings show that simultaneous changes in the geometric parameters of the atrium and the window-to-wall ratio of the building facades can lead to an 11.82% reduction in total energy consumption, a 32.65% reduction in cooling demand, and a 13.46% reduction in heating demand. Linear regression analysis with a coefficient of determination of 1.000 shows that the height of the atrium from the ceiling has the greatest impact on the difference in energy consumption and heating demand, while the window-to-wall ratio of the western and eastern facades has the greatest impact on the cooling demand with standardized coefficients of 0.360 and 0.309, respectively. The final conclusion is that although increasing the atrium dimensions improves the building s daylight performance, it significantly increases energy requirements at the same window-to-wall ratio. In contrast, reducing the window-to-wall ratio of building facades, along with providing daylighting and solar radiation through the atrium, can significantly reduce energy consumption without significantly reducing the useful daylight index. These findings can be used as a basis for developing atrium design criteria in commercial buildings in hot and dry climates.
Keywords : atrium geometry energy performance modeling energy simulation energy optimization computational design non dominated sorting genetic algorithm version 2 hot and dry climate mid rise commercial building