The Role of Atrium Geometric Parameters in Improving the Energy and Daylighting Performance of Office Buildings: A Review of Previous Studies
The Role of Atrium Geometric Parameters in Improving the Energy and Daylighting Performance of Office Buildings: A Review of Previous Studies
Fatemeh Sadat Hahemi1 Abbas Tarkashvand2 Haniyeh Sanaieian3
1) M.Sc. Student, Iran University of Science and Technology (IUST)
2) Assistant Professor, Iran University of Science and Technology (IUST)
3) Assistant Professor, Iran University of Science and Technology (IUST)
IOI Code
:
ABFG-ACAGBG
Publication :
12th.international Congress on Civil Engineering, Architecture, Art and Urban Development(12icsau.ir)
Abstract :
Office buildings are among the most significant research domains in sustainable architecture due to their high energy consumption and the simultaneous need to provide thermal comfort and adequate daylighting. As an effective architectural strategy for enhancing daylight access and improving indoor environmental quality, atriums play a significant role in building energy and daylighting performance. However, atrium performance is highly dependent on geometric characteristics, and inappropriate designs may increase solar heat gains, cooling loads, heating loads, glare, and reduce thermal comfort. This paper aims to review and analyze the theoretical foundations and previous studies regarding the influence of atrium geometric characteristics on the energy and daylighting performance of office buildings. Accordingly, the study first examines fundamental concepts, including atrium definition, its role in office buildings, performance-related benefits and challenges, key geometric parameters, and evaluation metrics for energy and daylighting performance. Subsequently, previous studies are reviewed and analyzed in two main categories: overall atrium geometric parameters and angular variables of atrium. The findings indicate that parameters such as plan aspect ratio, geometric form, height, height-to-width ratio, volume, skylight characteristics, and wall geometry significantly influence building energy and daylighting performance. Furthermore, interactions and, in some cases, trade-offs exist among different performance indicators, particularly energy consumption, daylight availability, and direct solar radiation control. The review also demonstrates that although variables such as orientation, inclination, and other geometric characteristics have been investigated in previous studies, the independent and simultaneous evaluation of the tilt and azimuth angles of atrium interior walls and their combined effects on multiple energy and daylighting performance metrics remain limited. Therefore, by synthesizing the current state of knowledge and identifying research gaps, this paper provides a theoretical framework for future studies on atrium design and optimization in office buildings.
Keywords : atrium geometric parameters office buildings energy performance daylighting sustainable architecture