The effect of hole distance from the edge of the flange and its optimal arrangement in seismic behavior of reduced beam section
The effect of hole distance from the edge of the flange and its optimal arrangement in seismic behavior of reduced beam section
Hamed Asgaran1 Farrokh Forootan2
1) Master of Science, Islamic Azad University, South Tehran Branch Email:
2) PhD, Islamic Azad University, Central Tehran Branch Email:
IOI Code
:
XCBK-EEDGE
Publication :
10th International Conference on Mechanical, Construction, Industrial and Civil Engineering(mmiconf.com)
Abstract :
The DF connection is a reduced cross section beam connection that has been suggested to reduce the cost of construction and easier implementation of the RBS connection by creating holes in the beam flange instead of the flange cut. In these connections, by reducing the cross-sectional area of the beam at a specified distance from the beam to the column and forming a plastic hinge in that area, a flexible fuse will be created that exhibits acceptable performance against cyclic loads. In this Paper, the effects of the hole distance from the beam flange edge that caused in order to reduce the section of beam, have been evaluated in seismic behavior of the beam connection. Four modes were considered based on FEMA s proposed equation for model selection, and for each mode 6 specimens were modeled by ABAQUS software with 10 pairs of holes on the bottom and upper beam flanges. A parametric study of maximum Von-Mises stresses in column edge, plastic strain diagrams in terms of time and distance from the column as well as hysteresis curves of the specimens showed that by increasing the hole distance from the flange edge, and the acceptable connection performance regarding AISC code will provided to ensure flexible seismic behavior as well as to reduce damage indices in complete joint penetration groove welding connection.
Keywords : reduced beam section connection hole distance from the flange edge seismic behavior damage index