Simultaneous determination of N-acetylcysteine and folic acid in the presence of unknown interference using a nanostructured modified sensor: application of chemometric approaches in the electrochemical studies

Simultaneous determination of N-acetylcysteine and folic acid in the presence of unknown interference using a nanostructured modified sensor: application of chemometric approaches in the electrochemical studies

Abbas Dadras1 Ali Benvidi2 Mohammad Karimi3 Salehe Abbasi4 Masud Rezaie nasab5

1) Yazd University Department of Chemistry Email:
2) Yazd University Department of Chemistry Email:
3) Yazd University Department of Textile Email:
4) Yazd University Department of Chemistry Email:
5) Yazd University Department of Chemistry Email:

IOI Code : XBCG-DCCZH
Publication : 13th Biennial Electrochemistry Seminar of Iran(elect13pguac.ir)
Abstract :
    N-acetylcysteine (N-AC) is a precursor in the formation of L -cysteine and the antioxidant glutathione in the body. It is a mucolytic agent used to reduce the viscosity of pulmonary secretions in respiratory disorders. [1]. It is also used as an antidote to paracetamol poisoning [1–3]. Another material which was investigated in the present study was folic acid (FA). FA is a water-soluble vitamin. It acts as a coenzyme in the regeneration of methionine from homocysteine. FA deficiency is a common cause of anemia and it is thought to increase the likelihood of heart attack and stroke [4]. In this work, a voltammetric method coupled with multivariate curve resolution-alternating least squares (MCR-ALS) was applied for the simultaneous determination of NAC and FA in the blood serum samples containing unknown interferences. Thus, a carbon paste electrode modified with bis (N-2-bromophenyl-salicydenaminato)nickel(II) and reduced graphene oxide (RGO) (Ni(II) /RGO/CPE) was used as an efficient electrochemical sensor. The modified electrode was characterized using different techniques such as scanning electron microscopy (SEM), and cyclic voltammetry methods. For the quantitative determination of NAC and FA with a high degree of overlapping electrochemical signal using the fabricated electrode, second-order voltammetric data was developed by changing the pulse height. The results obtained from MCR-ALS indicated that the linear ranges was 5.5-125.2 μM for NAC and 8.0-143.0 μM for FA and the detection limits were 3.37 and 4.43 μM, respectively. Also, after analyzing of the data using MCR-ALS, satisfactory recoveries for NAC and FA were obtained between 95.8-105.3% and 97.5-102.3%, for the blood serum sample, respectively. The designed method can be applied successfully for the simultaneous determination of NAC and FA in the complex systems with unknown interferences without the necessity of using separation technique.

Keywords : n acetylcysteine folic acid cyclic voltammetry