جستجو
Simultaneous determination of N-acetylcysteine and folic acid in the presence of unknown interference using a nanostructured modified sensor: application of chemometric approaches in the electrochemical studies
Abbas Dadras1 Ali Benvidi2 Mohammad Karimi3 Salehe Abbasi4 Masud Rezaie nasab5
Abstract :
N-acetylcysteine (N-AC) is a precursor in the formation of L -cysteine and the antioxidant glutathione in the body. It is a mucolytic agent used to reduce the viscosity of pulmonary secretions in respiratory disorders. [1]. It is also used as an antidote to paracetamol poisoning [1–3]. Another material which was investigated in the present study was folic acid (FA). FA is a water-soluble vitamin. It acts as a coenzyme in the regeneration of methionine from homocysteine. FA deficiency is a common cause of anemia and it is thought to increase the likelihood of heart attack and stroke [4]. In this work, a voltammetric method coupled with multivariate curve resolution-alternating least squares (MCR-ALS) was applied for the simultaneous determination of NAC and FA in the blood serum samples containing unknown interferences. Thus, a carbon paste electrode modified with bis (N-2-bromophenyl-salicydenaminato)nickel(II) and reduced graphene oxide (RGO) (Ni(II) /RGO/CPE) was used as an efficient electrochemical sensor. The modified electrode was characterized using different techniques such as scanning electron microscopy (SEM), and cyclic voltammetry methods. For the quantitative determination of NAC and FA with a high degree of overlapping electrochemical signal using the fabricated electrode, second-order voltammetric data was developed by changing the pulse height. The results obtained from MCR-ALS indicated that the linear ranges was 5.5-125.2 μM for NAC and 8.0-143.0 μM for FA and the detection limits were 3.37 and 4.43 μM, respectively. Also, after analyzing of the data using MCR-ALS, satisfactory recoveries for NAC and FA were obtained between 95.8-105.3% and 97.5-102.3%, for the blood serum sample, respectively. The designed method can be applied successfully for the simultaneous determination of NAC and FA in the complex systems with unknown interferences without the necessity of using separation technique.
Keywords : n acetylcysteine folic acid cyclic voltammetry
زبان مقاله : انگلیسی
محور مقاله : الکتروشیمی محاسباتی
محل انتشار : سیزدهمین سمینار دوسالانه الکتروشیمی انجمن شیمی ایران
آدرس وب سایت کنفرانس : elect13pguac.ir
کد IOI مقاله : XBCG-DCCZH
لینک مستقیم مقاله : https://isnac.ir/XBCG-DCCZH
سایر مقالات ارائه دهنده
- Modification of titanium anode electrode for ozone generation with metal oxides and nanocomposite
- Simultaneous determination of N-acetylcysteine and folic acid in the presence of unknown interference using a nanostructured modified sensor: application of chemometric approaches in the electrochemical studies
سایر مقالات محل انتشار
- Formation of CuO film due to corrosion on generator s neutral bar in Qom combined cycle power plant
- Investigation on the water tanks corrosion of water-steam unit in Isfahan oil refinery and its controlling process with photoelectrochemical approach
- Electrochemical determination of propranolol, using modified carbon paste electrode
- Electrochemical sensor for simple and sensitive ultra-trace detection of sunitinib in different samples
- Electrochemical Oxidation of 3,4-Dihydroxycinnamic acid in the Presence of 2-mercaptobenzimidazole Derivatives
- Pt nanoparticles supported on functionalized carbon nanoparticle and reduced graphene oxide nanosheets for electrooxidation formic acid
- Assessment of antioxidant activity and biosynthesis of silver nanoparticles by Corn silk aqueous extracts
- Mesoporous Layered double hydroxide nanoparticle/tetra bromophenol blue dye as a novel electrochemical platform for determination of ascorbic acid
- An electrochemical investigation on ZnO nanoparticles decorated methylene blue (MB/ZnONPs)
- Atorvastatin determination, using a novel electrochemical sensor
- Voltammetric PSA sensor based on the use of graphene oxide@polyanilline, and molecular imprinted polymer
- Construction of biocompatible molecular imprinting polymer based on chitosan and used of MWCNTs as a platform for electrochemical sensing of norepinephrine
- A novel sensor based on carbon paste electrode with Deep Eutectic Solvents for Enhanced Electrochemical Oxidation and Detection of Acyclovir
- Electroanalytical evaluation of Sarcosine as a new biomarker for prostate cancer using a carbon paste electrode modified with TiO2 nanoparticles
- High-specific electrochemical diagnosis of miRNA-541 using a restriction enzyme