جستجو
Robust and real-time detection of normal QRS using a novel processing method based on the topology of electrocardiogram reconstructed in phase space
Mahdi Zolfagharzadeh Kermani1 Seyed Mohammadreza Hashemi Golpayegani2 Ahmad Ebadi3
Abstract :
Designing automatic and real-time detection systems regarding cardiac diseases first requires an accurate detection of normal QRS complex of the heart s electrical activity (electrocardiogram). This research was conducted with the aim of achieving a topological pattern of normal QRS complex that is able to model the qualitative behavior specific to normal QRS complex from real-time electrocardiogram (ECG) time series. We believe that the geometric structures or topology of the points reconstructed out of ECG signal in phase space include richer information for classification of nonlinear signals and in addition to quantity, it provides the quality of trajectory or orbit of time series in the form of distance and angle in successive points as information of the dynamics governing the system. However, there is shortage of analytical tools for extraction of such information. In this research, a new processing method based on trajectory or orbit tracking reconstructed out of ECG signals in phase space was presented based on geographical directions. Eventually, a unique and special behavioral pattern of normal QRS was extracted and presented. In order to preserve the geometrical structures and the order of points reconstructed from time series in phase space, considering the chaotic nature of ECG signal, which is nonlinear and non-stationary, no noise removal and filtering have been done on the selected ECG. Among other advantages of the proposed algorithm are no application of windowing and segmentation onto the time series. Accordingly, in response to independence of the length of the time series and removing the error related to estimation of data length, one can dispense with preprocessing and it can lead to decreased computational load. Next, using databanks of Fantasia-Database and MIT-BIH Normal-Sinus-Rhythm-Database, the efficiency of the proposed processing method for robust detection of normal QRS was evaluated. The criteria of the positive predictive value, accuracy, sensitivity of 100%, and detection error rate of 0% were calculated.
Keywords : normal qrs detection topology phase space real time robust
زبان مقاله : انگلیسی
محور مقاله : علوم مهندسی
محل انتشار : کنفرانس بین المللی پژوهش در علوم و مهندسی
آدرس وب سایت کنفرانس : icrsie.com
کد IOI مقاله : XYDC-AGZFK
لینک مستقیم مقاله : https://isnac.ir/XYDC-AGZFK
نمایش چکیده فارسی
: https://isnac.ir/SA/XYDC-AGZFK
سایر مقالات محل انتشار
- استفاده از الگوریتم الگویی در جهت بهینه سازی برای تنظیم پارامترهای پایدار ساز سیستم قدرت تک ماشینه
- رویکرد کیفی نت ناب دراجتماع باگسترش عملیات کیفیت
- Sodium borohydride Synthesis of Iron Cobalt (FeCo) Nanorods
- مقایسه و ارزیابی رفتار لرزه ای قاب های بتن آرمه تقویت شده با مهاربند فولادی (inverted V-CBF) و دیوار برشی بتنی
- رابطه اضطراب اجتماعی و استعداد اعتیاد با خودشفقتی در بین نوجوانان
- بررسی عددی اثرات جت مصنوعی اوریفیس چندگانه بر انتقال حرارت
- اولویت بندی مناطق نمونه گردشگری ایران با استفاده از روش های تصمیم گیری چند معیاره
- پیش بینی استعداد اعتیاد در بین دانشجویان بر اساس متغیر های اجتناب شناختی و امید به زندگی
- کنترلگرTS-Fuzzy با جبران اغتشاش برای توربین بادی سرعت متغیر
- Effect of Gas Cap on Oil Production in Fractured Reservoir
- بهره برداری بهینه از شبکه های هوشمند متصل به واحدهای PV
- بررسی تأثیر مشوق های صادراتی بر توسعه صادرات کشاورزی«از دیدگاه صادرکنندگان» مطالعه ی موردی کلان شهر تهران سال 1394
- تاثیر فعالیت های فرهنگی هنری مراکز کانون پرورش فکری کودکان و نوجوانان بر رشد مهارتهای اجتماعی و خلاقیت نوجوانان دختر و پسر شهر تهران در سال 1394
- تحلیل انرژی نوین هسته ای با رویکرد پایداری و زیست محیطی
- تحلیل شکلگیری امنیت در منطقه خلیج فارس بر اساس نظریۀ امنیتی مکتب کپنهاگ ( امکان یا عدم امکان )