Proposing Novel Method for Medical Devices Sterilization Via a New Reactor Design with Applying Combination of O3/O2/UV Radiation with Rotational Forced Convection Flows
Mehrzad Zandieh1
Abstract :
Medical devices are necessary for safe and efficient prevention, diagnosis, therapy and renewal of sickness. The access of health-related development and advancement targets upon appropriate production, regulation, scheme, assessment, learning, management and use of medical devices that are of well quality, safe and suitable with the settings in which they are applied. Most medical and surgical devices used in healthcare facilities are built of materials and components that are heat stable and so undergo heat, firstly steam, sterilization. Sterilization annihilates all microorganisms on the surface of a material or in a liquid to prevent illness transfer related with the utilization of that item. The significance of what forms “sterile” is measured as a likelihood of sterility for each item to be sterilized. This likelihood is generally referred to as the sterility assurance level (SAL) of the final product and is described as the likelihood of a single viable microorganism happening on a final product after sterilization. In this new article, we proposed a new method for medical devices sterilization via a new reactor design with applying combination of O3(ozone)/O2(oxygen)/UV(ultraviolent) radiation with rotational forced convection flows.
Keywords : new method medical devices sterilization combination of o3/o2/uv radiation
زبان مقاله : انگلیسی
محور مقاله : مهندسی شیمی
محل انتشار : هفتمین کنفرانس بین المللی شیمی و مهندسی شیمی
آدرس وب سایت کنفرانس : ccce.ir
کد IOI مقاله : XCAG-EFHGB
لینک مستقیم مقاله : https://isnac.ir/XCAG-EFHGB
نمایش چکیده فارسی
: https://isnac.ir/SA/XCAG-EFHGB
سایر مقالات ارائه دهنده
- Investigating and Identifying Hazardous Points in Design of Processes and Parts of a PVC-Based Consumable Medical Sterile Suction Tube Manufacturing Factory with Assessing and Controlling Risks in Design Phase
- Investigating Process Risk Assessment and Controlling Risks in Decolorization Process of Colored Aqueous Solution by Advanced Oxidation Process with HAZOP Method
- Introducing Three Novel Proposed Models for Process Design of Recovery of Inactivated Refinery Platinum Catalysts
- Introducing a novel model for design, development and improvement of fermentation processes and bioreactors of production of biotechnological drugs according to new technologies
- A useful and concise overview of important mechanical and physicochemical tests for validation of packaging processes of sterile medical devices according to international standards
- Introducing novel applied solutions for resolving corrosion problems and controlling corrosion in refinery and petrochemical industries with using of coatings of novel and advanced materials
- Introducing novel proposed process models for purification of air polluted with different organic compounds
- Advanced applied models for establishment of HSE-MS in factories related to chemical engineering processes with emphasis on safety of processes
- Proposing Novel Method for Medical Devices Sterilization Via a New Reactor Design with Applying Combination of O3/O2/UV Radiation with Rotational Forced Convection Flows
- ANFIS modeling a decontamination process from water with MATLAB
- مروری مفید و علمی بر روی بخشهای مختلف استاندارد ایزو 14644 (ISO 14644) مختص کلین رومهای به کار رفته در فرآیندهای تولیدی حساس به پارتیکلها و ذرات هوابرد به ویژه در فرآیندهای تولید مواد غذایی, داروسازی و تولید تجهیزات پزشکی
- Procedure design of modeling a sterilization reactor with artificial neural network (ANN) using MATLAB
- ارائه طرح (Plan) کاربردی برای تجزیه و تحلیل نقاط خطرناک و نقاط کنترل بحرانی فرآیندی در فرآیندهای تولیدی یک کارخانه تولید دمنوشهای گیاهی با استفاده از اصول و رویکردهای HACCP
- شناسایی خطرات مرتبط با ایمنی فرآیندهای اکسیداسیون پیشرفته برای تصفیه آبها و پسابها و اقدامات کنترلی لازم برای کنترل خطرات این فرآیندها بر اساس نوع و ماهیت فرآیندها با رویکرد ایمنی و بهداشت
- مروری بر پژوهشهای انجام شده در زمینه راکتورهای پلاسمای پرتو الکترون
سایر مقالات محل انتشار
- Effects of drug targeting and smart drug delivery on direct drug delivery to target cells
- مروری بر روش های جداسازی غشایی با مطالعه موردی غشاهای RO
- Catalytic Performance of Titanum Oxide Nano-structured based on Ag-modified Molybdena in the Oxidative Dehydrogenation of propane
- مروری بر کاربرد نانو مواد در اصلاح ویژگی های شیمیایی و بهبود عملکرد آسفالت
- A Molecular Dynamics Study of Hydrogen Bonding in Poly(N-isopropylacrylamide)/Water as a Function of Temperature
- Comprehensive review of Municipal Wastewater Treatment Plants of Iran, in terms of Number, Processes, Capacities, Disadvantages
- جداسازی ناخالصی های فلزی از اسید نیتریک با استفاده از تکنیک میکروفیلتراسیون غشایی
- حذف صمغ از فرآوردههای نفتی به روش جذب سطحی با خاکهای رنگبر
- شبیهسازی فرآیند جذبNOx در آب با استفاده از نرم افزارAspen plus
- بررسی نظری برهمکنش داروی لنالیدوماید با نانو لوله های کربنی تک جداره عامل دار شده
- A Brief Review on Gold Metal-Synthesis Using Various Routes with Regard to Nanoscience
- بررسی پارامترهای توپولوژی نانولوله های کربنی تک جداره عامل دار شده با آزومتین و کاتکول به عنوان سیستم تحویل دارو
- بررسی تاثیر قطرداخلی لوله مغزی و فشار سر چاهی بر عملکرد یک چاه گازی
- بررسی عامل دار کردن MOF ها برای افزایش ظرفیت جذب CO2
- Sulfonated Polypyrrole/Au Nanocomposite Conductivity, Studied by Four-Point Probe