Properties of concrete treated by ChemConcrete-WP waterproofing admixture

Aref Sadeghi-Nik1 Farzad Zivari2 Mohammad Afrazi3 Mohammadreza Rezaeian4 Masoud Ahmadi5

Abstract :
Penetration of water and corrosive chemicals is the main reason for the major chemical and physical deteriorations of concrete infrastructures and pavements, which shortens the service-life of concrete and results in an annual cost of billions of dollars to the national economies. Extensive research has been carried out to extend the life span and improve the durability of concrete using different integral waterproofing admixtures, membranes, and surface coatings. It has been believed that the use of an effective integral waterproofing admixture has many advantages over surface protection methods because an integrally waterproof concrete does not require ongoing maintenance, is not vulnerable to degradation, does not include labor work, saves the construction time, and can be used where membranes or surface coatings are impossible or too complex to apply. ChemConcrete-WP is a commercially available, hybrid integral waterproofing admixture used to develop a waterproof concrete and improve the durability of concrete structures and pavements. This research evaluated the effects of this commercial admixture on compressive strength, flexural strength, bulk water absorption, water contact angle, and chloride resistance of concrete treated by ChemConcrete-WP. The water absorption tests results were also compared with the existing literature on similar waterproofing admixtures. The findings of this research showed that ChemConcrete-WP waterproofing admixture increased the water contact angle of concrete from 0 º to 93 º, respectively. Balk water absorption of 28-day cured concrete specimens reduced from 6.38% to below 1% because of employing this admixture. Compressive and flexural strengths of concrete increased from 41 MPa to 48 MPa and from 5.50 MPa to 6.30 MPa, respectively. Chloride resistance of concrete treated by ChemConcrete-WP was also significantly increased in comparison to the untreated control concrete. A comparison between the results of this research and the existing literature showed that ChemConcrete-WP waterproofing admixture is more effective than six other commercial counterparts that are presented in this research in terms of reducing the water absorption rate and developing durable/watertight concrete while simultaneously improving the strength properties as well.

Keywords : concrete waterproofing admixtures waterproof concrete water absorption durability chloride resistance chemconcrete wp


زبان مقاله : انگلیسی
محور مقاله : مهندسی عمران و توسعه پایدار
محل انتشار : نهمین کنگره سالانه بین المللی عمران، معماری و توسعه شهری
آدرس وب سایت کنفرانس : 9icsau.ir
کد IOI مقاله : XGFB-KDAZZ
لینک مستقیم مقاله : https://isnac.ir/XGFB-KDAZZ

سایر مقالات محل انتشار
  1. معماری بیومیمتیک؛ تقلید انسان از طبیعت
  2. امکان¬سنجی استفاده از سیستم بادبند¬های زانویی لچکی تجدید طراحی¬شده در قاب¬های فولادی در سازه¬های کوتاه مرتبه و در مقاوم¬سازی لرزه¬ای سازه¬های موجود
  3. بررسی مناسب¬ترین محل اتصال سیستم بادبند زانویی لچکی در ستون جهت کاستن تنش¬ها در ستون
  4. بررسی رفتار مفاصل پلاستیک تشکیل شده در سیستم¬های قاب ساده و خمشی همراه با بادبند زانویی-لچکی با هدف بهینه کردن مقاومت آن در مقابل فروریزی
  5. مهندسی ارزش در خصوص سیستم های تهویه مطبوع در ساختمان¬های مسکونی و استفاده از PCM در صنعت ساختمان
  6. پیش بینی اراضی مناسب برای توسعه شهری بندرعباس
  7. طراحی باغ شفابخش بیماران سرطانی در شهر ساری با تکیه بر شاخصه های بازشناسی طبیعت
  8. تجارب واقدامات جهانی اسکان غیر رسمی در ایران ،ترکیه،مراکش،برزیل
  9. نقش مؤلفه‌های کیفیت فضای باز جمعی مجتمع مسکونی بر بهبود افسردگی بانوان سالمند
  10. مروری بر روابط ارائه شده جهت محاسبه Tp در زلزله های میدان نزدیک
  11. تبیین نقش باغ ایرانی در فضاهای مسکونی به عنوان عامل سلامت روح و روان
  12. تصفیه آبهای آلوده به مواد نفتی به روش MBR در پالایشگاه تهران
  13. نقش جریان های اقتصادی در امکان شکل پذیری پیوند های روستایی _شهری در کرج و حوزه ی پیرامونی آن با تاکید بر پایداری سکونتگاه ها
  14. بررسی تاثیر افزودن ژل حاوی میکروسیلیس و فوق روان کننده در مقادیر مصرف مختلف بر تغییر رفتار مقاومتی و نفوذ پذیری مخلوط های بتنی
  15. بهبود مدیریت بهره‌برداری از فضاهای درمانی و مراقبتی با شناسایی شاخص‌های کلیدی و ایجاد نشاط، جذابیت و حس مثبت در بیمارستان‌های کودکان تهران