جستجو
Checking the Materials and Designs of Knee Replacement Implants, Stress Contour of Tibial Tray during Gait Cycle, and Complications from Knee Surgery in Engineering and Medicine field
Fatemeh Poodineh hajipour1 Mehdi Movahed2
Abstract :
During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. Implant Designs including: Posterior-Stabilized , Cruciate-Retaining and Bicruciate-Retaining Designs. The metal parts of the implant are made of titanium or cobalt-chromium based alloys. The plastic parts are made of ultra-high molecular weight polyethylene. Some implants are made of ceramics or ceramic/metal mixtures. Whether metal or ceramic, implants weigh between 15 and 20 ounces, depending on the size selected. Stress contour of tibial tray during gait cycle has showed in this article. result show that: patellar replacement has little influence on tibio femoral kinematics and mechanical properties, although it produced a slightly increased tibial tray stress and patellar replacement significantly reduced the kinematics and mechanical performances in the patellofemoral joint during the gait cycle ; patellar tilting, internal rotation,and anterior-posterior translation were all significantly increased compared to the patellar retaining method; meanwhile, patellar replacement altered the stress distribution in the patellofemoral joint, resulting in an increased high-stress area.
Keywords : implant materials knee surgery implant designs knee replacement implants
زبان مقاله : انگلیسی
محور مقاله : علوم مهندسی
محل انتشار : سومین کنگره بین المللی علوم، مهندسی و تکنولوژی - هامبورگ
آدرس وب سایت کنفرانس : germanconf.com
کد IOI مقاله : XCZE-EEGAZ
لینک مستقیم مقاله : https://isnac.ir/XCZE-EEGAZ
سایر مقالات ارائه دهنده
- Checking the Materials and Designs of Knee Replacement Implants, Stress Contour of Tibial Tray during Gait Cycle, and Complications from Knee Surgery in Engineering and Medicine field
- Checking the Causes, Diagnosis, Prevention and Treatment in Ventilator-associated pneumonia (VAP) and Compliance of the Lung in this Disease
سایر مقالات محل انتشار
- بررسی و تحلیل علل و عوامل بروز فروچاله ها در دشت کبودراهنگ
- Design and Analysis of High-Power Device Based on PZT/AlGaN/GaN by Ferroelectric-Gate Heterojunction
- Evaluation of Nursing Information System Implementation in two General Hospitals Affiliated to Zahedan University of Medical Sciences in Southeast Iran: Nurses’ Viewpoints
- Examining the main cause of failure in coiled tubing in the oil industry (Real Case)
- نگاشت تئوری بازیها در عملکرد پروتکل Bit Torrent در سیستمهای توزیعشده شیگرا
- Surprising function of methanolic extracts of seed of Peganum Harmala compared with it,s leaf on apoptosis induced T2DM in pancreas of male wistar rats
- هوشمندسازی ساختار صنعت نفت و گاز باگرایش مهندسی فناوری اطلاعات
- شبيه سازي انتقال حرارت دريک لوله مارپيچ سه بعدي همراه با نانوسيال غيرنيوتوني و تحت تاثير ميدان مغناطيسي يکنواخت
- A New Approach to Clustering Clickstream Data using Fuzzy Inference Engine
- بررسی تطبیقی آزادی مشروط در حقوق ایران و فرانسه با نگاهی به رویکردهای بین المللی این نهاد
- positive and negative aspects of nanocomposites utilization in food packaging
- نقش عمان در راهبرد امنیتی ایران در تنگه هرمز: مطالعه موردی ژئوپلیتیک فرهنگی، قومی و سیاسی عمان
- سیاست مهاجرت و روابط کشورهای اروپایی
- Effect of Garcia Lorca s Written Structure on Iranian Literary and Dramatic Works
- مطالعه ی شیوه ی بازنمایی دیو درنگاره های سیاه قلم و مقایسه آن با متون کهن ادبی