جستجو
Solar energy gain comparison for one axis three position sun tracking versus fixed PV system: Case study Urmia-Iran
morteza mohammadi1 morteza khalilian2
Abstract :
In this study, the performance results of using one-axis three position sun tracker system have been analyzed in period of one year operation. The theoretical study has been done for two identical PV systems (95WP). Calculated data has been comprised and analyzed at Urmia climate in 2014. PV system calculation performance were carried out, at first while PV system were in a fixed position and then PV system has studied when one-axis three position sun tracker system were performed. The amount of produce electricity for one year is 0.24 (MW) with energy rating of 2567.73 KWh/KW p, for fixed PV system. In comprise with fixed tilt angle PV system 27% more electricity produced in tracking system. Annual produced electricity for one-axis three position sun tracker system is 0.31 (MW) with 3231.37 KWh/KW p
Keywords :
One axis three position sun tracking، Solar energy، Photovoltaic، PV performance
زبان مقاله : انگلیسی
محور مقاله : علوم مهندسی
محل انتشار : کنگره بین المللی علوم و مهندسی ژاپن - TOKYO
آدرس وب سایت کنفرانس : tuicet.com
ارسال کننده : مرتضی محمدی
کد IOI مقاله : XBHB-DHGHG
لینک مستقیم مقاله : https://isnac.ir/XBHB-DHGHG
مقالات مشابه
- بررسی برج های خورشیدی در قالب معماری پایدار
- The Use of Solar Energy in Permanent Architecture
- بهینه ساز مصرف انرژی با الگوبرداری از عناصر سنتی اقلیمی معماری ایران
- اثرتغییر زاویه تابش نور روی چگالی جریان، توان و بازده کوانتوم خروجی در سلول¬های خورشیدی آلی دو لایه با ساختار ترکیبی P3HT:PCBM
- طراحی وبررسی سیستم های فتوولتاییک
- سنجش سرمایش سیستم پیشنهادی سرمایش در اقلیم گرم و مرطوب ایران
- نظام طراحی مجتمع تجاری، تفریحی و رفاهی با رویکرد معماری پایدار و همساز با طبیعت
- راهکارهای پایداری برای بهینه سازی مصرف انرژی در خانه سالمندان با استفاده از شاخص هاي زيست اقليمي (مطالعة موردي : شمالِ شهرتهران)
- آشنایی با سیستم فتوولتائیک و نحوه ی طراحی و نصب آن در پهنه بندی اقلیمی ایران
- تحلیل هزینه-منفعت برای حرکت به سمت خانههای با انرژی پایدار از منظر پدافند غیرعامل نمونه کلانشهر تهران
- بهره گیری از انرژی خورشیدی بعنوان انرژی تجدید پذیر درطراحی ساختمانهای مسکونی
- ساختمانهای برپایه انرژی جلبک
- Optimal management of microgrids including photovoltaic/wind/diesel using GPSO-GM algorithm
- Coordination between a Wind turbine, a Photovoltaic and a Fuel Cell in a microgid
- استفاده از انرژی خورشیدی در جهت کاهش مصرف انرژی در ساختمان های آموزشی
سایر مقالات ارائه دهنده
سایر مقالات محل انتشار
- The role of architecture compatible with climate in context-based architecture (case study: Bushehr and Yazd)
- واکاوی مفاهیم و کارکردهای معماری سبز در طراحی بناهای بلند مرتبه
- مدیریت ایده پردازی و نقش آن در تحول مهندسی معماری
- Investigating the components of creativity promotion in Gilan s native architecture Case Study: Sustainable Architecture
- Investigation of the beams and columns connection with infill plate on the structural behavior of the steel plate shear walls
- بررسی رفتار لرزه ای اتصالات مرکب پیچی تحت تأثیر مقاومت فشاری بتن پرکننده ستونCFST تحت بار چرخه ای
- Nonlinear Incremental Dynamic Analysis
- Data Mining: To determine the optimal order point in inventory control system
- Applications of nanoparticles containing ginger (Zingiber officinale) extract to improve the stability of encapsulated ginger
- بررسی کاربرد هسته خرما در غنی سازی نان
- Determination of the protective radius of the arrester in the distribution network based on the Isokraunic indexes
- کاربرد تجزیه و تحلیل سیستم اندازه گیری در صنعت خودروسازی: مروری بر ادبیات موضوع
- Solar energy gain comparison for one axis three position sun tracking versus fixed PV system: Case study Urmia-Iran
- برآورد ارتفاع موج با استفاده از تصاویر رادار سار (SAR) در منطقه دریایی امیرآباد به روش رگرسیون خطی
- بررسی خوانش نیچه از سرگذشت دیُنوسُس و آیین آن